How to Choose The Best Products
Molecular Interaction Analyzer QCM
Selection Guide
Key points for product selection.
AFFINIX Q8 | AFFINIX QN Pro | AFFINIX QN μ | AFFNIX QN | |
---|---|---|---|---|
Installation of a simple and easy interaction analyzer. | ○ | ○ | ◎ | ◎ |
Measurement of coupling constant and rate constant. | ◎ | ○ | ○ | ○ |
Reduction of the consumption of samples. | ◎ | ○ | ○ | △ |
There are many samples to be measured. | ◎ | ○ | ○ | ○ |
Mix organic solvents in the measurement solution. | △ | △ | △ | ○ |
Immobilization using organic solvents. |
○**
|
○*
|
○*
|
◎ |
Quantitative determination of the viscoelasticity of adsorbates. | - | ◎ | - | - |
Quantitative determination of the viscosity of the solution. | - | ◎ | - | - |
**Please use a crystal separated type sensor.
****Please remove the measuring cup before use.
◎ : Especially recommended ○ : Recommended △ : not very good - : not measurable
AFFINIX Q8
AFFINIX Q8 uses 100μL low-capacity sensors and performs simultaneous measurement with 8 sensors. It can meet various measurement needs
by improving the efficiency of experiments with 8 sensors simultaneous measurement and reducing the sample volume needed in experiments.
AFFINIX QN Pro
The AFFINIX QN Pro is a device that uses a new detection method(QCM-A)to analyze not only intermolecular interactions but also the viscoelasticity of solutions and molecules.
AFFINIX QN μ
The capacity of the measurement vessel is small so that the amount of sample can be saved. However, since the material of the measurement vessel is acrylic, it is weak against chemicals such as strong acid, strong alkali, and organic solvent. It is recommended for applications of water solubility.
If the unit is replaced, it can be converted to another model. One PC can control up to four units.
The advantage of using four units of AFFINIX QNμ is that the experimental system (Timing of temperature control and injection) is conducted completely independently.
AFFINIX QN
Although the capacity of the measurement vessel is large, the ceramic sensor chip is excellent in high heat treatment and drug resistance, and there are many substances that can be fixed to the sensor.
If the unit is replaced, it can be converted to another model. One PC can control up to four units.
How to Choose The Best Products
HOW TO
- Vacuum Tech Basics
- Fundamentals of Vacuum Pumps (Low to Medium Vacuum)
- Fundamentals of Vacuum Pumps (High Vacuum)
- Fundamentals of Vacuum Valves
- Fundamentals of Vacuum Gauges
- Fundamentals of Quartz Crystal Oscillation Type Deposition Controller
- Fundamentals of Leak Detection
- Fundamentals of High-Speed Spectroscopic Ellipsometer
- Fundamentals of Gas Analyzer (Process Gas Monitor)
- The Others
- How to Choose The Best Products
- Old Models vs. New Models
- Troubleshooting