Qulee QCS Ver.4.2|Software for Gas Analysis|Software for Gas Analysis|Gas Analyzer(Process Gas Monitor)|Products|ULVAC SHOWCASE

Software for Gas Analysis

Software for Gas Analysis

Qulee QCS Ver.4.2

アルバック

"Qulee QCS" is a software package for gas analyzers and process monitors manufactured by ULVAC."Qulee QCS" is suitable for all Quadrupole gas spectrometers made by ULVAC.
Older software can be upgraded to this QCS version.Data acquisition and saving data is carried out by simple key s trokes.

Features

  • QCS is Standard software for the Qulee Series RGA units (Windows 8/10/11)
    Qulee QCS Ver.4.2
  • Simple Operation
    Easy operation with use of short cut buttons
  • Various Measurement Modes
    Options include scan mode, trend mode, analog mode, sensitivitycalibration mode
  • Leak-test Function
    Easy leak check by using the helium leak test mode
  • Indication of Gas Composition Name
    Able to display the gas composition name in scan and trend mode
  • Recipe Setting
    Measurement-condition control by creating simple recipe programs
  • Able to integrate up to 32 RGA units
    (Qulee BGM2/Qulee HGM2) Simultaneously control up to 32 units (Ethernet)
  • Various Functions
    Able to combine data
    Able to subtract background noise.
    Able to integrate various functions of the region measured.
    Ion source and secondary electron multiplier protection and maintenance management function.
    Traceability management function of the analysis tube. (patent:5016031)
    Simultaneous recording analog data in 2 points.
    Possible to set 2 partial pressure outputs. (in the trend mode measurement)
    Able to lock password
  • Data Storing Function Using CSV Format
    Capable of storing in CSV format retreavable by
    using the table calculation software

Specifications

Model Qulee QCS Ver. 4.2
OS Windows 8/10/11
Interface Ethernet
Sensor Number Up to 32 units (with Ethernet)
Sensor model Qulee BGM2/Qulee CGM2/QuleeHGM2/Qulee RGM2
Recipe 100 (70 in the user area)
Sweep speed 50, 100, 200, 500, 1000, 2000 msec/mass
Sampling interval Auto,0.5 to 1000 sec (in the trend mode), 1 to 1000 sec (in the scan mode)
Measurement end time Continuous,or free setting
Measurement mode Scan mode: Measuring the mass spectrum in various mass range (model dependent)
Trend mode: Measuring partial presuure to time up to 20 channels
Leak-test mode: One-touch helium leak testing
Analog mode: Analog wave measurement for mass number calibration
Sensitivity-calibration mode:Calibration of the sensitivity of the SEM detector
DEGAS mode: Controlling the electron bombardment type outgassing of ionsource (except RGM)
Indication og gas compositon name Able to indicate the gas composition name in scan and trend mode function
Function Background subtraction / integration of mesured area / Able to combine data / Able to lock Password
Analog Input 0 to 10V (2 points)
Set-point Partial pressure set-points in 2 channels (Error and warning) (only in trend mode)
Electron energy for ionization Fixed (HGM2 25 to 70eV / RGM2 20 to 70eV)
Status Check

Error detection (communication error, filament break, RF error, interlock)

Total running time of Filament and SEM

Display

Vertial axis:

Horizontal axis:Mass number (scan mode and analog mode)and time (trend mode).

       Able to change and scroll the Horizonal axis range.Indicate saved data(able to indicate saved data during measurement) Bar chart and line chart is simultaneously indicated.

Data save Auto save,or saved after mesurement
The file is named by combination of time and date at strting point of mesurement. (Auto save)
Filename is selectable.Saving place can be set
File can be converted to CSV format (for Past Data)
Print data Graph displayd in scan,trend or analog mode can be prnted
Setting screen range to be printed / Setting data color & radius of trend graph
Option Host communication facilities:
・Mesurement data of trendy mode can be transmitted through RS232C commucation by a demand fron host computer.
Analog Output:
・During the trendy mode mesurement, an analog og the nuclear number data which appointed every mesurement interval is performed.
Recommendation of PC

Ethernet port,CD-ROM drive,HDD:30MB (except mesurement data).RAM:4GB or more.

CPU:Corei5 or higher.(8 units or more/Corei7 or higher).

Display are:1280×1024 or more

該非判定結果報告書 Download

SDS Download

Accessories and Consumables

Instruction Manuals and Specifications Download

Applications Download

Technical drawings Download

Technical Data Download