Model: HR|Multi-Stage Roots Type Dry Vacuum Pump|Rough&Middle Vacuum Pump|Products|ULVAC SHOWCASE

Multi-Stage Roots Type Dry Vacuum Pump Model: HR

ULVAC

For more information on ULVAC products, purchase, and/or consideration, click here.

Uniformity of high temperature distribution. It is possible to exhaust the sublimates generated by CVD and etching processes in a gaseous state.

Features

  • Uniform high temparature distribution pump
    The Model:HR pump is designed to keep uniform high temparature for applications that require a heated pump, heated gas lines, and/or heated exhaust lines
    The Model:UR pump is enable to keep higher temparature than “Model:HR.
  • Excellent helium pumping capability
    Canned motor for safety and ease of maintenance
  • Power failure protection
    Pump withstands power interruptions of up to 1000ms duration.
  • Superior resistance for corrosive gas:
    Internal components are specially treated providing a high degree of surface hardness and corrosion resistance. This prevents wear and corrosion of internal pump parts when exposed to corrosive gasses.
  • Communication function:
    Pump data including warnings and alarms are able to be exported. Extensive pump control is available.

Applications

  • CVD equipment
  • Etching equipment
  • Ashing equipment
  • ALD, ALH etc

Specifications

Model HR60 HR90 HR300 HR600 HR1200
Pump DRP HR60 HR90 HR60 HR90 HR90
MBP - - PRC-003A PRC-006A PRC-012A
Max.
pumping
speed
50Hz m3/h
(L/min)
62(1030) 112(1860) 359(5,980) 653(10,900) 1,012(16,900)
60Hz m3/h
(L/min)
80(1333) 126(2100) 365(6,080) 701(11,700) 1,051(17,500)
Ultimate pressure Pa 5 0.67
Max. inlet pressure   Atmospheric pressure *1
Max. exhaust pressure Pa 1.0 to Atmospheric pressure
Inlet diameter (type CE) VG50(KF50) VG80(KF50) VG80(KF80) VG100(KF100)
Outlet diameter KF40
Weight kg 180 245 275 370 420
Power Three
phase
VAC
(Hz)
200(50/60), 220(60)
Current At
ultimate
pressure
A 7.1
(at 200V)
11.2
(at 200V)
7.8
(at 200V)
12.9
(at 200V)
15.4
(at 200V)
At max.
load
A 7.3
(at 200V)
11.8
(at 200V)
8.1
(at 200V)
13.8
(at 200V)
18.9
(at 200V)
Cooling water Supply
pressure
MPa 0.1 - 0.3    0.1 - 0.3
Cooling water In/Out
differrencepressure
MPa >0.1 
Cooling water Flow rate L/min >5.0
N2 gas Supply
pressure
MPa 0.1 - 0.5
Regula-
ted
pressure
MPa 0.05 0.1
N2 purge Shaft
purge
SLM 5
Gas ballast SLM 0 - 45

*1 HR300, HR600 and HR1200 should all be operated below 200Pa (1.5 Torr).

Dimension drawing

  • HR60HR60_en_size.png
  • HR90HR90_en_size.png
  • HR180HR180_en_size.jpg
  • HR300HR300_en_size.jpg
  • HR600HR600_en_size.jpg
  • HR1200HR1200_en_size.jpg

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]

I Accept