GHD-101|GHD Series|Oil Rotary Vacuum Pump|Rough&Middle Vacuum Pump|Products|ULVAC SHOWCASE

Oil Rotary Vacuum Pump

GHD Series

GHD-101

アルバック

Two-stage / with cord, and switch/with thermal protector

Outline

This is a rotary blade type vacuum pump that uses lubricating oil. A vacuum pump with low noise, low vibration and high reliability. GHD series uses a magnetic coupling.

Features and Cautions on use

  • Wide range voltage motor and correspond to CE, cTUVus.
  • Magnet coupling for no oil leakage from shaft seal and realized longer lifetime.
  • Integrated check valve below the inlet port for backflow prevention.

Specification

Item Unit 50Hz 60Hz
Actual Pumping Speed L/min 100 120
Ultimate Pressure Pa 0.67
Ultimate Pressure (G.V. open) Pa 6.7
Motor Output W 300
Recommended oil   R-2
Oil capacity mL 1,000
Weight kg 22
Inlet, Outlet port diameter mm KF-25, G1
Ambient temperature 7~40
Overall dimensions mm 150(W) × 413.5(L) × 234.5(H)
RoHS applied  
Ultimate pressure is the value measured by Pirani gauge. When measured with a Mcleod vacuum gauge, the value will be an order of magnitude lower for vacuum pumps with an ultimate pressure of 1.3Pa or less.

Power Supply/Voltage

Voltage Certificate Remarks
Single phase, 100V CE, TUV, cTUVus GHD-101A
Single phase, 115-120V CE, TUV, cTUVus GHD-101B
Single phase, 200V CE, TUV, cTUVus GHD-101C
Single phase, 220-240V CE, TUV, cTUVus GHD-101D

■TUV Certification: A high-quality product that complies with European standards as assessed by an international third party that conducts product safety testing and certification.

Outline Drawing

GHD-101_en_drawing.png

Pumping Speed Curves

GHD-101_en_curve.png

Remarks

  • Oil is deteriorated with operating, and becomes the factor of performance shortage. A decrease and the dirt of oil are confirmed, and please regularly add and replace it.
  • This pump has an unti-sack valve function that is effective to
  • prevent the oil back streaming when the pump stops.
  • The function is not 100% guranteed.
  • If operation is performed at high pressure, oil mist is generated at the exhaust side.
  • There is a risk of explosion. Never block the outlet or operate the pump with equipment mounted at the outlet side that blocks the passage of gas. Otherwise, the internal pump pressure increases causing the pump to explode, the oil level gauge to protrude or the motor to be overloaded.
  • It is a pump only in the room. Please do not set it up in the place, that rain and water splash, and outdoors.

該非判定結果報告書 Download

SDS Download

Instruction Manuals and Specifications Download

Applications Download

Technical drawings Download

Technical Data Download

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]