GHD-031|Magnetic Coupling Type|Oil Rotary Vacuum Pump|Rough&Middle Vacuum Pump|Products|ULVAC SHOWCASE

Oil Rotary Vacuum Pump

Magnetic Coupling Type

GHD-031

アルバック

Two-stage / with cord, and switch/with thermal protector

Features

  • Small size but high exhaust speed.
  • Compact size suitable for device integration.
  • The magnet coupling structure eliminates oil leakage from the shaft seal and achieves long life.
  • There is no oil contamination in the vacuum chamber due to the installation of the check valve directly below the intake pipe.
  • Low noise and low vibration.
  • Corresponds to diversification of power cord by power cord inlet and outlet.
  • The exhaust speed is stable due to the installation of the forced oil supply mechanism.
  • Operation from atmospheric pressure is possible.
  • Easy connection with flanged parts and connection by knock pins on internal parts.

Specification

Item Unit 50Hz 60Hz
Actual Pumping Speed L/min 30 36
Ultimate Pressure Pa 0.67
Motor Output W 100
Recommended oil   R-2
Oil capacity mL 370
Weight kg 9.3
Inlet, Outlet port diameter mm KF-16, G3/4
Ambient temperature 7~40
Overall dimensions mm 120(W) × 288.5(L) × 163(H)
RoHS applied  
Ultimate pressure is the value measured by Pirani gauge. When measured with a Mcleod vacuum gauge, the value will be an order of magnitude lower for vacuum pumps with an ultimate pressure of 1.3Pa or less.

Power Supply/Voltage

Voltage Certificate Remarks
Single phase, 100-120V CE, TUV, cTUVus GHD-031A
Single phase, 200-240V CE, TUV, cTUVus GHD-031B

■TUV Certification: A high-quality product that complies with European standards as assessed by an international third party that conducts product safety testing and certification.

Outline Drawing

GHD-031_en_drawing.png

Pumping Speed Curves

GHD-031_en_curve.png

Remarks

  • Oil is deteriorated with operating, and becomes the factor of performance shortage. A decrease and the dirt of oil are confirmed, and please regularly add and replace it.
  • This pump has an unti-sack valve function that is effective to
  • prevent the oil back streaming when the pump stops.
  • The function is not 100% guranteed.
  • If operation is performed at high pressure, oil mist is generated at the exhaust side.
  • There is a risk of explosion. Never block the outlet or operate the pump with equipment mounted at the outlet side that blocks the passage of gas. Otherwise, the internal pump pressure increases causing the pump to explode, the oil level gauge to protrude or the motor to be overloaded.
  • It is a pump only in the room. Please do not set it up in the place, that rain and water splash, and outdoors.

該非判定結果報告書 Download

SDS Download

Accessories and Consumables

Instruction Manuals and Specifications Download

Applications Download

Technical drawings Download

Technical Data Download