Oil Rotary Vacuum Pump
Magnetic Coupling Type
GHD-031
アルバック
Two-stage / with cord, and switch/with thermal protector
Features
- Small size but high exhaust speed.
- Compact size suitable for device integration.
- The magnet coupling structure eliminates oil leakage from the shaft seal and achieves long life.
- There is no oil contamination in the vacuum chamber due to the installation of the check valve directly below the intake pipe.
- Low noise and low vibration.
- Corresponds to diversification of power cord by power cord inlet and outlet.
- The exhaust speed is stable due to the installation of the forced oil supply mechanism.
- Operation from atmospheric pressure is possible.
- Easy connection with flanged parts and connection by knock pins on internal parts.
Specification
Item | Unit | 50Hz | 60Hz |
Actual Pumping Speed | L/min | 30 | 36 |
Ultimate Pressure | Pa | 0.67 | |
Motor Output | W | 100 | |
Recommended oil | R-2 | ||
Oil capacity | mL | 370 | |
Weight | kg | 9.3 | |
Inlet, Outlet port diameter | mm | KF-16, G3/4 | |
Ambient temperature | ℃ | 7~40 | |
Overall dimensions | mm | 120(W) × 288.5(L) × 163(H) | |
RoHS applied | ● |
Ultimate pressure is the value measured by Pirani gauge. When measured with a Mcleod vacuum gauge, the value will be an order of magnitude lower for vacuum pumps with an ultimate pressure of 1.3Pa or less.
Power Supply/Voltage
Voltage | Certificate | Remarks |
Single phase, 100-120V | CE, TUV, cTUVus | GHD-031A |
Single phase, 200-240V | CE, TUV, cTUVus | GHD-031B |
■TUV Certification: A high-quality product that complies with European standards as assessed by an international third party that conducts product safety testing and certification.
Outline Drawing
Pumping Speed Curves
Remarks
- Oil is deteriorated with operating, and becomes the factor of performance shortage. A decrease and the dirt of oil are confirmed, and please regularly add and replace it.
- This pump has an unti-sack valve function that is effective to
- prevent the oil back streaming when the pump stops.
- The function is not 100% guranteed.
- If operation is performed at high pressure, oil mist is generated at the exhaust side.
- There is a risk of explosion. Never block the outlet or operate the pump with equipment mounted at the outlet side that blocks the passage of gas. Otherwise, the internal pump pressure increases causing the pump to explode, the oil level gauge to protrude or the motor to be overloaded.
- It is a pump only in the room. Please do not set it up in the place, that rain and water splash, and outdoors.