Model: DIS-90|Scroll Type Dry Vacuum Pump|Rough&Middle Vacuum Pump|Products|ULVAC SHOWCASE

Scroll Type Dry Vacuum Pump Model: DIS-90

ULVAC

For more information on ULVAC products, purchase, and/or consideration, click here.

Double wrap / terminal only (without cord) with switch / with thermal protector / with air flash

Features

  • Compact size with large displacement.
  • The highest level of ultimate pressure for dry vacuum pumps.
  • Safety design with built-in automatic reset type thermal protector.
  • Suppresses moisture condensation by air flush.

Applications

  • Analytical equipment.
  • Gas recovery system.
  • Coating equipment.
  • Back pump for TMP.
  • Helium leak detector.
  • Manufacturing process for semiconductor.

Specification

  Unit 50Hz 60Hz
Actual pumping speed※1 L/min 90 108
Ultimate pressure Pa (kPa) 5
Motor※2   Single phase, 100/115/200/230V, 150W, 4P Capacitor start/run
Full load current A 2.6/1.3/1.6 2.1/2.2/1.1/1.1
(100/200/230V) (100/115/200/230V)
Weight kg 14
Inlet flange   KF-25
Outlet pipe diameter   KF-16
Ambient temperature deg. C 5 - 40
Water vapor handing g/day ≦5 以下 (AFopen※3, Room temperature 25℃, Humidity 60% or less)
Noise level dB ≦52 (AFopen※3, ≦57)
External dimensions mm 214(W) X 308(L) X 225(H)
※1:Actual pumping speed is about 1.2 times the Actual pumping speed when a gas at atmospheric pressure is sucked.
※2:Power supply plug and Power supply code are not included.
※3:AF=Air flush
The air flush operation not only discharges the water remaining in the pump, but also has the effect of recovering the Ultimate pressure.

Corresponding certificate/Voltage

Model Applicable standard※ CEDeclartion of confirmity 1Φ
100V
1Φ
200V
3Φ
200V
3Φ
400V
DIS-90 cTUV ✓ ✓
(Can be switched by changing the terminal plate)
※cTUV certification: This is a high quality product that complies with Canadian standards, as assessed by an international third party that conducts product safety testing and certification.

Caution

1
If the pump evacuates the powder or the product, it might be damaged.
Please use the inlet filter etc.
2
Do not evacuate gas which is hazardous to humans or explosive, flammable, or corrosive. If done, it can cause failure by gas, explosion or ignite.

Dimension drawing

zu_dis090e.png

Pumping Speed Curves

curve_dis090.png

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]

I Accept