Software for Gas Analysis Model:Qulee QCS Ver.4.2
ULVAC

For more information on ULVAC products, purchase, and/or consideration, click here.
Older software can be upgraded to this QCS version.Data acquisition and saving data is carried out by simple key s trokes.
Features
- QCS is Standard software for the “Model:Qulee” RGA units (Windows 8/10/11)
Qulee QCS Ver.4.2 - Simple Operation
Easy operation with use of short cut buttons - Various Measurement Modes
Options include scan mode, trend mode, analog mode, sensitivitycalibration mode - Leak-test Function
Easy leak check by using the helium leak test mode - Indication of Gas Composition Name
Able to display the gas composition name in scan and trend mode - Recipe Setting
Measurement-condition control by creating simple recipe programs - Able to integrate up to 32 RGA units
(Qulee BGM2/Qulee HGM2) Simultaneously control up to 32 units (Ethernet) - Various Functions
Able to combine data
Able to subtract background noise.
Able to integrate various functions of the region measured.
Ion source and secondary electron multiplier protection and maintenance management function.
Traceability management function of the analysis tube. (patent:5016031)
Simultaneous recording analog data in 2 points.
Possible to set 2 partial pressure outputs. (in the trend mode measurement)
Able to lock password - Data Storing Function Using CSV Format
Capable of storing in CSV format retreavable by
using the table calculation software
Specifications
Model | Qulee QCS Ver. 4.2 |
OS | Windows 8/10/11 |
Interface | Ethernet |
Sensor Number | Up to 32 units (with Ethernet) |
Sensor model | Qulee BGM2/Qulee CGM2/QuleeHGM2/Qulee RGM2 |
Recipe | 100 (70 in the user area) |
Sweep speed | 50, 100, 200, 500, 1000, 2000 msec/mass |
Sampling interval | Auto,0.5 to 1000 sec (in the trend mode), 1 to 1000 sec (in the scan mode) |
Measurement end time | Continuous,or free setting |
Measurement mode | Scan mode: Measuring the mass spectrum in various mass range (model dependent) |
Trend mode: Measuring partial presuure to time up to 20 channels | |
Leak-test mode: One-touch helium leak testing | |
Analog mode: Analog wave measurement for mass number calibration | |
Sensitivity-calibration mode:Calibration of the sensitivity of the SEM detector | |
DEGAS mode: Controlling the electron bombardment type outgassing of ionsource (except RGM) | |
Indication og gas compositon name | Able to indicate the gas composition name in scan and trend mode function |
Function | Background subtraction / integration of mesured area / Able to combine data / Able to lock Password |
Analog Input | 0 to 10V (2 points) |
Set-point | Partial pressure set-points in 2 channels (Error and warning) (only in trend mode) |
Electron energy for ionization | Fixed (HGM2 25 to 70eV / RGM2 20 to 70eV) |
Status Check |
Error detection (communication error, filament break, RF error, interlock) Total running time of Filament and SEM |
Display |
Vertial axis: Horizontal axis:Mass number (scan mode and analog mode)and time (trend mode). Able to change and scroll the Horizonal axis range.Indicate saved data(able to indicate saved data during measurement) Bar chart and line chart is simultaneously indicated. |
Data save | Auto save,or saved after mesurement |
The file is named by combination of time and date at strting point of mesurement. (Auto save) | |
Filename is selectable.Saving place can be set | |
File can be converted to CSV format (for Past Data) | |
Print data | Graph displayd in scan,trend or analog mode can be prnted |
Setting screen range to be printed / Setting data color & radius of trend graph | |
Option | Host communication facilities: |
・Mesurement data of trendy mode can be transmitted through RS232C commucation by a demand fron host computer. | |
Analog Output: | |
・During the trendy mode mesurement, an analog og the nuclear number data which appointed every mesurement interval is performed. | |
Recommendation of PC |
Ethernet port,CD-ROM drive,HDD:30MB (except mesurement data).RAM:4GB or more. CPU:Corei5 or higher.(8 units or more/Corei7 or higher). Display are:1280×1024 or more |