Pirani Vacuum Gauge

Transducer Type

SW100

SW100-A / R

アルバック

New Product


Renewed design and improved to be more user-friendly taking over the highly shock resistant sensor head and anti-corrosive filament material.

Features

  • Heigher usability: Easy set point setting (SW100-A) or status checking, etc. by connecting Windows PC/Android.
  • Flexible analog output: Analog output form selectable from preset typical ones (SW100).
  • Wide Range Measurement: Measureable pressure range: 5×10-2 to 1.0×10+5Pa (3.75 x 10-4 to 760Torr, 5 x 10-4 to 1,013mbar)
  • Excellent shock resistance: Shock-resistant-design sensor head.
  • Excellent corrosion resistance: Filament material: Pt (platinum)
  • High maintenability: Easy exchange of sensor head (one-touch atmospheric pressure adjustment and zero point adjustment)
  • Serial communication spec: RS232C/RS485 (SW100-R)

Applications

  • FPD/semiconductor/electric parts production equipment (inline type / batch type)
  • Pumping dolly for manufacturing home appliance or automobile
  • Industrial equipment such as vacuum furnaces
  • Various analyzing equipment

Specifications

Model SW100-A SW100-R
Type Analog output type Serial communication type
Connectable sensor head 1pc
Applicable gauge sensor head SWP-16 (NW16) , SWP-25 (NW25) , SWP-R1/8 (R1/8) , SWP-P18 (φ18) ,
SWP-P15 (φ15) , SWP-CF16 (ICF034) , SWP-1S (ASME BPE sanitary 1")
Measurable pressure range 5.0×10-2 ~ 1.0×10+5 Pa
Accuracy *1 1×10-1 Pa ~ 1×10+4 Pa : ±10%
5.0×10-2 ~ 1.0×10-1 Pa, 1×10+4 Pa ~ 1×10+5 Pa : ±20%
Repeatability 1×10-1 Pa ~ 1×10+4 Pa : ±2%
Sampling time 60 ms, 5x moving average
Value output     Output voltage DC 0 to 10V
Pressure indication (Log) 1.7V to 8.0V 1V/decade
Update time 50 ms
Resolution 3 mV
Error ±3 mV
Output impedance 10 Ω
Adjustment Zero point / atmosphericpressure, adjustment clear
Control input signals Zero point / atmosphericpressure, adjustment clear
Open collector input, negative logic
-
Control output signals Sensor error, set point 1/2
Open collector output, negative logic
Rating: 30 VMAX , 50 mAMAX , 70 mW
-
Communication D-sub15-pin (M2.6 screw)
USB Type-C *USB Type-C is available only for cmommunication by UL-MOBI.
Serial communication - RS232C / RS485
Baud rate - 9600 / 19200 / 38400 bps
Memory function - EEPROM backup
LED display POWER/ERROR: Power, error display
SET-1: Set point 1
SET-2: Set point 2
Matreial of sensor head Filament: Pt
Others: SUS304(SWP-1S: SUS316L/Ra<0.5),FeNiCo, Ni, Au, Glass, Ceramic
Sensor breaking pressure 2×10+5 Pa (1.5 x 10+3 Torr, 2 x 10+3 mbar) (absolute pressure)
*Need separate measures as a capacity to resist pressure, such as flange and clamp.
Operating temperature range 10 to 40℃
Operating humidity range 15 to 80% (not condensing)
Storage temperature -20℃ to 65℃ (at non-energizing, not condensing)
Maximum baking temperature 150℃ (sensor head only, without SW100)
*When baking, data such as accuracy can be out of spec.
*Operating temperature range of SW100 is 10℃ to 40℃.
IP rating IP30
Fixing position Free
Power supply voltage Rated voltage DC 24V
Vaoltage variation range DC 14V to 30VMAX (-42/+25%)(ripple, Noise 1% or less)
Constant 2.0W
At power on 4.8W
Over voltage category Category 1
*Connect to a circuit where the transient voltage is low enough.
Input / output connector D-sub15-pin (M2.6 screw)
USB Type-C
*USB Type-C is available only for cmommunication by UL-MOBI.
Weight Approx. 105g (sensor unit only)
Dimension W x D x H 48mm x 30mm x 74mm (sensor unit only)
Standard accessories Quick manual
Option Sensor head SWP-16 (NW16) , SWP-25 (NW25) , SWP-R1/8 (R1/8) , SWP-P18 (φ18) ,
SWP-P15 (φ15) , SWP-CF16 (ICF034) , SWP-1S (ASME BPE sanitary 1")
Display unit Model ISG1(DC24V sepc)
Display cable 2m, 5m, 10m (between SW100 - ISG1)
I/O Connector D-sub15-socket(M2.6mm screw)
Others Test certificate, tracability certificate, general calibration certificate, JCSS calibration certificate
Applicable standard CE

*1:Value after atmospheric pressure and zero point adjustment. Please do atmospheric pressure adjustment and zero point adjustment before using.
The calibration gas is N2. Please note that some errors can occur when measuring other kinds of gases.

Image of coneection with PC/smartphone

SW100_PC.pngSW100_mobile.png

Application software "UL-MOBI"

For PC UL-MOBI_Windows You can download from here
For smatphone UL-MOBI_Android Google Play  SW100_QR.png

Compatible devices

PC Windows10 64bit or later
Smartphone Android 6 or later, USB TypeC

Ordering code

contact the nearest distributor regarding other combinations than the following

Main unit Sensor head Fitting type Ordering code
SW100-A (analog output spec) SWP-16 NW16 210007036100
SWP-25 NW25 210007036200
SWP-R1/8 R1/8 210007036300
SWP-P18 Φ18 210007036400
SWP-P15 Φ15 210007036500
SWP-CF16 ICF034 210007036600
Without sensorhead 210007036700
SW100-R (serial communication spec) SWP-16 NW16 210007037100
SWP-25 NW25 210007037200
SWP-R1/8 R1/8 210007037300
SWP-P18 Φ18 210007037400
SWP-P15 Φ15 210007037500
SWP-CF16 ICF034 210007037600
Without sensorhead 210007037700

gage_sw100.png

該非判定結果報告書 Download

SDS Download

Accessories and Consumables

Instruction Manuals and Specifications Download

Applications Download

Technical drawings Download

Technical Data Download

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]

I Accept