Model:VLPーU20|Vacuum Angle Valve|Vacuum Valve|Products|ULVAC SHOWCASE

Vacuum Angle Valve Model:VLPーU20

ULVAC

SHOWCASE

For more information on ULVAC products, purchase, and/or consideration, click here.

ULVAC's vacuum valves were developed based on a wealth of technology and experience in the vacuum field.
We offer a variety of products that meet a wide range of needs from atmospheric pressure to ultra-high vacuum.

Specifications

Model VLP-U
Maximum allowable differential pressure on valve plate
(Positive pressure) MPa
0.10
Maximum allowable differential pressure on valve plate
(Counter pressure) n/a
Not available
Maximum allowable differential pressure in opening direction
(Positive pressure) kPa
1.0
Maximum allowable differential pressure in opening direction
(Counter pressure) n/a
Not available
Plate seal O-ring
Feedthrough O-ring
Actuation Double-acting cylinder
External leak rate*1 Pa・m3/s ≦1.3E-7
Internal leak rate*1 Pa・m3/s ≦1.3E-7
Operating pressure range(absolute pressure) Pa Atm.~1.0E-5
Bakeout temperature(when stopping)*2 60
Operating ambient temperature  ℃ 5~40
Fluid temperature ℃ 5~40
Heating & cooling speed ℃/h ≦30
Operating ambient Non-corrosive
Fluid Non-corrosive
Compressed air to cylinder MPaG 0.40~0.55
Warranted operation cycle*3 100,000
Orientation Vertical
Position indicator Optional (sell separately)
Material of major parts (Vacuum side) Steel 400 with Ni plating
Material of major parts (Atmosphere side) Steel 400 with Ni plating + acrylic painting
Seal material (Vacuum side) Nitrile rubber
Grease (Vacuum side) Highly purified paraffin oil
Attachment for lifting None/td>
RoHS Complied

Detail of specification  VLP-U

Flange VF500
Conductance in opening position*4 L/s 9,198
Cylinder capacity cc 9,040
Compressed air fitting Rc3/4
Operating speed (open) *5 sec 7.0±0.5
Operating speed (close) *5 sec 7.0±0.5
Weight kg 310
Height dimension (A) mm 1,530
Center-to-flange dimension (B) mm 380

*1 Leak rate does not include permeation in O-ring. External leak during opening and closing is not regulated in the case of O-ring shaft seal feedthrough.
*2 Do not open and close during bakeout.
*3 See instruction manual for detail.
*4 Conductance is based on molecular flow at 20℃ (68F) air.
*5 Adjust operation speed to make its value equal to specified value by using a speed controller.

Inquiry about this product

1. I have read and agree to the Privacy Policy

Agree 

2. Enter the product name or model number.*

3. Select the status of the inquiry product.*

4. Request for *

5.  If you selected "I would like to consult about a problem or malfunction" in step 4, please enter the product number or serial number.

6. Comment *

​​​​​​​

Contact Information

Remember Me
​​​​​​​
​​​​​​​

The ULVAC email distribution office sends information about vacuum, such as product information, product maintenance, and web seminars. Click "Allow" if you wish.

Email delivery from us

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]

I Accept