A2K-20K|A2K Series|Abnormal Discharge Prevention Unit|DC Power Supply|Products|ULVAC SHOWCASE

Abnormal Discharge Prevention Unit

A2K Series

A2K-20K

アルバック

In the reactive sputtering processes, the A2K series abnormal discharge prevention unit applies positive voltage pulses to a DC power generator to neutralize the charge on the target.
This unit can be easily mounted to existing equipment, and it achieves improvements in yield ratio and throughput at low cost.

Features

  • High throughput
    Makes high power input possible by reducing abnormal
  • Reduces substrate damage
    Capable of reducing substrate damage caused by arcs
  • Inhibits substrate temperature
    Capable of inhibiting substrate temperature compared to RF sputtering
  • Simple connectivity
    Can be easily connected to existing equipment *1
  • Variable inversion pulse frequency
    Possible range: A2KH-25/50:1kHz to 20kHz, A2K-20K/40K:1kHz to 50kHz
  • Pulse synchronization system
    Output pulses for multiple A2K units can be synchronized *2 *3
  • Capable of large capacities through master/slave connections
    Up to six A2K-20K/40K units can operate in parallel

Application: Pulse synchronization system

a2kdata.jpg

When cathodes are close in the same chamber and they are opposite of each other or when there is interference in the discharge of multiple A2K units, the A2K inversion pulse can be set to in-phase or reverse phase by using the phase control function to prevent discharge interference. *3 *4

*1:Can be connected to ULVAC DC power supplies
*2:Pulse synchronization and parallel operation is not possible when using mixed A2KH-25,50 and A2K-20K, 40K units
*3:The A2KH-25/50 requires an external synchronization unit (PHSM/PHSS)
*4:The A2K-20K/40K is only capable of in-phase phase control

Applications

  • Reactive sputtering equipment for FPD
  • Reactive sputtering equipment for industrial coating
  • Reactive sputtering equipment for color TFT

Specifications

Model A2KH-25 A2KH-50 A2K-20K A2K-40K
Control power input Input AC90 to 110V AC100 to 240V
Frequency Single phase 50/60Hz
Power 100VA 120VA 400VA
Leak current 1mA or less
Input specification operating voltage -100 to -800V
operating current 0 to 25A 0 to 50A 0 to 50A 0 to 100A
Input structure Connector connection Terminal block or connector connection Connector connection
Output specification Pulse range 5μs/10μs ( Internal switch switching ) 1 to 18μs (There is a frequency limitation)
Oscillating frequency ・Pulse range 5μs:
 2,5,10,15,20kHz
・Pulse range 10μs:
 1,2.5,5,7.5,10kHz
1 to 50KHz
Variable in 1KHz increments
Inversion pulse voltage 10 to 20% of the DC power generator output voltages. ( It depends on a load impedance )
Withstand voltage continuous operation -1500Vdc
Parallel operation Nothing Up to 6units can be controlled *5
Cooling method Forced air-cooling
Dimension(W×D×H) 238×450×149mm 430×450×149mm 483×630×177mm
Weight 16kg 27kg 30kg 45kg
Applicable standard RoHs

Ambient operating temperature 5℃ to 40℃ (no condensation)
Operating environment: Avoid direct sunlight, heat, dust, vibration, and without corrosive gas.
*5: A2K-20K and A2K-40K cannot be used together.

該非判定結果報告書 Download

SDS Download

Accessories and Consumables

Instruction Manuals and Specifications Download

Applications Download

Technical drawings Download

Technical Data Download

This website use cookies to obtain and use access data to understand the convenience and usage of customers. If you agree to use cookies, click "I Accept".
[Privacy Plicy] [Cookie Policy]

I Accept